TECHNICAL GUIDE
AFFINITY
MODELS: PV8*UH
GAS-FIRED
HIGH EFFICIENCY TWO STAGE VARIABLE
UPFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx
80% AFUE
NATURAL GAS
57 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
246759-YTG-D-0407
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
Provides increased comfort level & very quiet unit opera-
tion
Field Selectable delay timer allows two stage operation w/
single stage thermostat
Acoustically insulated blower compartment for reduced
blower sound level
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
100% shut off main gas valve for extra safety.
Variable Speed ECM with large, quiet blower.
ClimaTrak Technology allows dealer to customize comfort
settings based on regional location.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum
comfort.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance
or service.
Insulated blower compartment for quiet operation.
Independent door removal for greater durability and ease
of access.
Low NOx models have been designed to meet specific
code requirements.
Low NOx models may not be converted to propane unless
screens are removed.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - TECHNICAL GUIDE

TECHNICAL GUIDEAFFINITY MODELS: PV8*UHGAS-FIREDHIGH EFFICIENCY TWO STAGE VARIABLE UPFLOW/HORIZONTAL FURNACESSTANDARD & Low NOx 80% AFUENATURAL GAS

Page 2 - CABINET AND DUCT DIMENSIONS

246759-YTG-D-04072 Unitary Products Group FRONTA40B3/426-3/41-1/21-1/4C205/85/8B24-3/4BOTTOM IMAGERETURN ENDTOP IMAGESUPPLY ENDD4” DIA. VENTCONNECTION

Page 3 - Unitary Products Group 3

246759-YTG-D-0407Unitary Products Group 3Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.Wire

Page 4 - AIR FLOW DATA

246759-YTG-D-04074 Unitary Products GroupAIR FLOW DATAHIGH / LOW SPEED COOLING AND HEAT PUMP CFMPV8A12(N,L)060UH11 PV8A12(N,L)080UH11 Jumper SettingsH

Page 5 - FILTER PERFORMANCE

246759-YTG-D-0407Unitary Products Group 5HORIZONTAL SIDEWALL VENTINGFor applications where vertical venting is not possible, theonly approved method o

Page 6 - ACCESSORIES

246759-YTG-D-04076 Unitary Products GroupACCESSORIESPROPANE (LP) CONVERSION KIT - 1NP0347 - All unitsThis accessory conversion kit may be used to conv

Page 7 - Unitary Products Group 7

246759-YTG-D-0407Unitary Products Group 7For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document availa

Page 8 - Group Drive 73069

Subject to change without notice. Printed in U.S.A. 246759-YTG-D-0407Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 24